Products

JGGY Electrical (jggyelectrical.com) was established in 2007, specializing in the supply and manufacturing medium voltage electric Vacuum circuit Breaker, MV switch, Load break switch, Air-insulated switchgear, Disconnector, Cutout fuse, Surge Arrester, etc.

Over the years, JGGY has been successfully used in important fields such as electric power, communications, chemicals, mining, metallurgy, transportation, petroleum, and railways.

Feel free to contact us for a quotation or click on the products you are interested in to view the details.

Outdoor 36KV FKW-36 Over line disconnector

outdoor AC high voltage isolate switch (hereinafter referred to as load break switch)

36kV 40.5kV fixed type VCB vacuum circuit breakers VS1-40.5

Vacuum circuit breaker is the most commonly used type of high-voltage circuit breaker, mainly divided into two types: indoor type and outdoor type. We mainly focus on indoor 10-40KV vacuum circuit breakers.

35KV 40.5KV withdrawable type vacuum circuit breaker VCB VS1-40.5 1600A

VS1-40.5 VCB indoor high voltage vacuum circuit breaker is used in KYN61-40.5 switchgear. Mainly used in rated voltage 40.5kV, three-phase AC 50Hz power system

12KV 1600A Vacuum circuit breaker VD4 type VSG VS1-12 draw-out type

Rated current from 630A to 4000A and rated short circuit breaking current from 20kA to 50kA satisfies re quirements of various customers.

CH3-10Q/150 contact box 630-1250A

It provides different specifications based on the size of electric current for the user’s choice

CH3-10Q/180 contact box 1250A

It provides different specifications based on the size of electric current for the user’s choice

CH3-10Q/190 contact box 1600A

It provides different specifications based on the size of electric current for the user’s choice

CH3-10Q/208 contact box 1600-2000A

It provides different specifications based on the size of electric current for the user’s choice

CH3-10Q/250 contact box 2500-3150A

It provides different specifications based on the size of electric current for the user’s choice

CH3-10Q/270(230) contact box 4000A

It provides different specifications based on the size of electric current for the user’s choice

JGGY Electrical adopts a modern production mode, has a group of experts and technicians who have been engaged in the production of electric vacuums and switch for many years. 80% of the high-voltage parts are designed and processed by itself, and it has obtained a number of invention patents every year. All aspects of production and management strictly implement and implement ISO9001 standards, and a corporate office information platform network has been established. CAD and CAM software technology applications are adopted from the whole process of product design, research and development and quality inspection, which greatly reduces product development and production cycle.

Leave A Message