//
Product overview
ZW30A-40.5 is a three-phase AC 50HZ high-voltage switchgear. It is mainly used for the control and protection of 40.5kv power transmission and transformation systems. It can also be used for normal operation and short-circuit protection of urban and rural power grids and industrial and mining enterprises. It can also be used as It is especially suitable for places with frequent operations when connecting circuit breakers and switching capacitor banks.
This product is equipped with CT17-IVB type spring energy storage operating mechanism, which can remotely control electric energy storage, electric closing and opening operations, and can also manually store energy on site and manual opening and closing operations. In addition, the ZW30A-40.5 outdoor high-voltage vacuum circuit breaker is developed based on the ZW30-40.5 outdoor high-voltage sulfur hexafluoride circuit breaker. It is an external current transformer and equipped with a CT17 spring operating mechanism. The three-pole body is installed on a common chassis, and the operating mechanism is located in the center below the chassis. A current transformer bracket is installed on the chassis, and an outdoor independent current transformer is placed on top. The three poles of the circuit breaker operate in mechanical linkage, and the gas between the poles is connected with copper tubes. The arc extinguishing chamber is located in the upper porcelain sleeve. It adopts the principle of vacuum arc extinguishing chamber. The vacuum arc extinguishing chamber is made of products from well-known manufacturers.
Product characteristics
1. It adopts a vacuum arc extinguishing chamber, uses SF6 gas as the auxiliary insulation medium, and is equipped with a spring operating mechanism to achieve complete oil-free operation;
2. Excellent breaking performance and long electrical life of 20 times;
3. Can break a single capacitor bank current of 630A without re-ignition;
4. Long mechanical life, up to 10,000 times, reliable action, frequent operation, and low noise;
5. It has out-of-step breaking capability and can be used as a contact circuit breaker;
6. According to user requirements, no CT or up to 12 CTs can be attached;
7. The product has beautiful appearance, strong anti-corrosion ability, simple structure, long maintenance cycle and easy maintenance.
12KV air LBS load break switch MV electric by manual ISARC series
indoor HV air load break switch is a 3-phase AC 50Hz 36kV indoor switchgear equipment.
Russia indoor 10KV load break switch with fuse ВНА-Л-10/630
24KV Indoor AC MV SF6 LBS Load Break Switch, suitable for protecting the 10kV, 24kV and 35kV power system's on load situation
ABB similar FN18-12 series 12KV Indoor load break switch LBS
ABB NALF 12KV load break switch FN18-12 LBS with fuse holder
manufacturer FN7 12KV LBS Indoor load break switch with fuse holder for RMU
Indoor AC High/Medium Voltage Vacuum Load Break switch 12KV LBS
FZN25/FZRN25 type indoor 12KV HV MV vacuum load break switch LBS
FN5-12D Indoor LBS 12KV MV air load break switch for RMU
ABB NAL/FN18-24D 24KV LBS load break switch indoor air
FN7-24D 24KV LBS Medium voltage overload switch load break switch with earth switch
indoor HV air load break switch is a 3-phase AC 50Hz 12kV indoor switch equipment.
Indoor AC High Voltage SF6 Load Break Switch and LBS-Fuse Combination are used for the three-phase AC 50/60Hz RMU and terminal power station.
FN5-24 series 24KV LBS MV load break switch with earth switch or fuse holder for air RMU
ABB type NALF 24KV FN18-24R LBS load break switch
12KV LBS high voltage vacuum load break switch by motor
12KV HV load break switch and fuse combination electrical appliance
Medium Voltage Vacuum Load Break switch HV MV LBS 36-40KV Indoor AC
FKN12 24KV air load break switch indoor MV LBS
FN7-24R AC and HV indoor air load break switch 24KV MV LBS manufacturer
FN7-12D 12KV LBS indoor Medium voltage load break switch with earthing switch
ABB NAL series 12KV LBS medium voltage load break switch for RMU similar as
Russia ВНА-10 Indoor 10KV Load break switch with earch switch VNA-L-10/630-20zp
LW3-12/630-20 primary and secondary fusion sulfur six new circuit switch is a new generation product developed by our company in response to the new requirements of the State Grid's primary and secondary synthetic sleeve switches for network access.
LW8A-40.5 outdoor porcelain column high-voltage sulfur hexafluoride circuit breaker is suitable for power systems with AC 50Hz and rated voltage 40.5kV.
This product can be equipped with CT14 spring mechanism.
The circuit breaker is an outdoor small porcelain column structure, equipped with a CT14 spring operating mechanism
LW16-40.5 side-mounted and center-mounted types are used for outdoor devices in AC 50Hz three-phase power systems.
LW24-40.5(G)/T2500(3150)-31.5 type six-oxide circuit breaker is an outdoor three-phase AC 50HZ high-voltage power transmission and transformation equipment.
The product has excellent breaking performance. It adopts a compressed gas type silencing chamber and has a long electrical life.
The LW36-40.5 outdoor high-voltage sulfur hexafluoride circuit breaker is a three-phase AC 50H outdoor high-voltage electrical equipment
LW□-40.5 outdoor high-voltage sulfur hexafluoride circuit breaker (hereinafter referred to as the circuit breaker) is a three-pole AC 50Hz outdoor high-voltage switching device.
The circuit breaker uses sulfur hexafluoride (SF6) gas as the arc extinguishing medium.
The circuit breaker uses sulfur hexafluoride (SF6) gas as the arc extinguishing medium.
The circuit breaker uses sulfur hexafluoride (SF6) gas as the arc extinguishing medium.
It is suitable for AC 50Hz (60z) and 126kV power systems. It is the control and protection equipment of the power system and can also be used as a contact circuit breaker.
LW35-126 self-energized sulfur hexafluoride circuit breaker outdoor AC three-pole 50Hz high-voltage power transmission and transformation equipment is used to open and close rated current, fault current or conversion lines to realize the protection, control and operation of the power transmission and transformation system.
LW36-126/3150-40 self-energized AC high-voltage sulfur hexafluoride circuit breaker is an outdoor product, suitable for altitudes not exceeding 2,000 meters (products can be designed for altitudes above 3,000 meters), and the ambient temperature is not lower than -40°C.
LW□-252 self-energizing sulfur hexafluoride circuit breaker is an outdoor AC three-pole 50H high-voltage power transmission and transformation equipment.
The LN2-40.5 indoor high-voltage SF6 circuit breaker is an indoor device in the AC 50Hz three-phase system and can be used for protection and control in industrial and mining enterprises, power plants, and substations (stations).
SW2-66 (SW2-72.5 abroad) oil-less circuit breaker is an outdoor three-phase AC 50Hz high-voltage power equipment.
AB-3S-12 outdoor high-voltage fast permanent magnet vacuum circuit breaker adopts the principle of vacuum arc extinguishing and permanent magnet operating mechanism, integrating microprocessing technology, modern network communication technology and new switch manufacturing materials.
Using a vacuum arc extinguishing chamber, air insulation, and an electric spring operating mechanism, the product has strong arc extinguishing ability, many short-circuit opening times, no fire and explosion hazard, and is easy to operate.
The FZW28-12 series outdoor AC high-voltage demarcation vacuum load switch is suitable for outdoor three-phase AC power distribution systems with a rated voltage of 12KV and a rated frequency of 50H.
FZW28-12 series outdoor AC high-voltage boundary vacuum load switch is suitable for outdoor three-phase AC power distribution systems with a rated voltage of 12KV and a rated frequency of 50Hz. It is used to open and close load currents and close short-circuit currents.
The ZW32-12 outdoor AC high-voltage vacuum circuit breaker (hereinafter referred to as the circuit breaker) is an outdoor power distribution equipment with a rated voltage of 12kV and a three-phase AC 50Hz.
ZW32Y-12 outdoor AC high-voltage prepaid vacuum circuit breaker is suitable for use as prepaid high-voltage metering in power systems with three-phase AC 50Hz and rated power 12kV.
ZW43-12 outdoor high-voltage vacuum circuit breaker is a miniaturized product of ZW32 circuit breaker.
ZW32-24 outdoor high-voltage vacuum circuit breaker (hereinafter referred to as the circuit breaker) is an outdoor power distribution equipment with a rated voltage of 24kV and three-phase AC 50Hz.
ZW32-40.5 outdoor AC high-voltage demarcation vacuum circuit breaker is mainly composed of integrated solid-sealed poles, current transformers, operating mechanisms and boxes.
ZW7-40.5 series outdoor high-voltage vacuum circuit breaker (hereinafter referred to as "circuit breaker") is used in AC 50Hz, 40.5kV three-phase power systems to divide and combine load current, overload current and short-circuit current.
ZW17-40.5 outdoor high-voltage vacuum circuit breaker is an outdoor high-voltage electrical equipment with three-phase AC 50Hz and rated voltage 40.5KV.
ZW30A-40.5 is a three-phase AC 50HZ high-voltage switchgear. It is mainly used for the control and protection of 40.5kv power transmission and transformation systems.
Copyright © 2021 By JGGY Electrical.com