Transformer

Transformer is one of the important electrical equipment in power system, it is similar to power transformer, is used to convert circuit voltage or current. However, the purpose of the power transformer switching voltage and current, is to transfer the power, voltage or current transformer transformation, the purpose of measuring and monitoring circuit voltage or current. In general, power transformer capacity is big, the change of the voltage or current error, transformer capacity is small, the change of the voltage or current error is small. In the measuring circuit, which is used to convert current, the current meter and relay is called a current transformer, power transformer is used to convert voltage, the voltage meter and relay of power transformer is called voltage transformer.

LFS-10 HV CT indoor 10KV current transformer

Category:Switchgear&HVCTBrand:JGGYElectricModel:LFS-10Power:10KVFOBPort:Ningbo/ShanghaiTermsofPy

LMZB3-10 series current transformer 10KV CT

Category:Switchgear&HVCTBrand:JGGYElectricModel:LMZB3-10Power:10KVFOBPort:Ningbo/ShanghaiTermsof

LQJ-10 10KV current transformer indoor high voltage CT

Category:Switchgear&HVCTBrand:JGGYElectricModel:LQJ-10Power:10KVFOBPort:Ningbo/ShanghaiTermsofPy

LZJ8-10 HV 10KV CT indoor current transformer

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZJ8-10Power:10KVFOBPort:Ningbo/ShanghaiTermsofP

LZX-10 indoor current transformer 10KV CT

It's similar to power transformer and also used to transformer voltage or current in the circuit.

LZZB7-35 current transformer medium voltage 35KV CT

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZZB7-35Power:35KVFOBPort:Ningbo/ShanghaiTermsof

LZZB9-24 indoor high voltage 24KV current transformer

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZZB9-24Power:24KVFOBPort:Ningbo/ShanghaiTermsof

LZZBJ4-35 series 35-40KV current transformer

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZZBJ4-35Power:35KVFOBPort:Ningbo/ShanghaiTermso

LZZBJ9-12 indoor 12KV current transformer

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZZBJ9-12Power:12KVFOBPort:Ningbo/ShanghaiTermso

LZZBJ9-35Q indoor current transformer 35kv CT

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZZBJ9-35QPower:35-40KVFOBPort:Ningbo/ShanghaiTe

The classification of the transformer:

  1. According to the principle of classification: can be divided into capacitive voltage transformer and voltage transformer electromagnetic voltage transformer, current transformer are electromagnetic current transformer.

  2. According to the winding insulation medium classification, there are dry, pouring, oil-immersed and inflatable (SF6).

  3. According to use classification: can be divided into two broad categories, voltage transformer, current transformer, can divide again for measuring, protection, special purpose and precise four classes.

  4. According to the installation site classification: can be divided into indoor type and outdoor type two kinds.

  5. According to the number of phase voltage transformer classification: can be divided into two kinds of single-phase, three-phase.

  6. Voltage transformer windings by several categories: duplex winding, three-winding two kinds.

  7. The classification of the current transformer according to the installation method: wear a wall type, support type and loading type 3 kinds.

  8. The classification of the current transformer according to the current ratio: a single variable ratio and changeable than two.