MV Vacuum Circuit Breaker (VCB)

What is a vacuum circuit breaker?

A vacuum circuit breaker is a circuit breaker quenching arc in a vacuum medium. The on-off, on-off, and associated arc breaking operations with current contacts are carried out in the vacuum chamber of the circuit breaker, known as the vacuum circuit breaker.

Vacuum as arc extinguishing medium in circuit breaker is called vacuum circuit breaker because the vacuum has superior arc extinguishing performance so that it has high insulation strength. This applies to most standard voltage applications, as for higher voltages, vacuum techniques are developed but are not commercially viable.


VSG-24 indoor high voltage 24KV VCB vacuum circuit breaker for power grid switchgear

As a protection and control unit for power grid equipment and industrial and mining enterprise power design

ZW20-12 outdoor column high voltage vacuum circuit breaker 12KV VCB recloser with SF6

Mainly used for opening closing the power system load current, overload current and short - circuit current

ZW32-12 series outdoor high voltage vacuum circuit breaker 12KV MV VCB with controller

12KV MV VCB outdoor high voltage vacuum circuit breaker with controller

ZW32-24 outdoor high voltage vacuum circuit breaker 24KV VCB

As the power grid's breaking switch, it can realize the distribution network automation after installation of the controller.

ZW32 series 40KV outdoor high voltage vacuum circuit breaker

basic functions such as breaking and closing load current, overload current and short circuit current

ZW43-12 permanent magnet outdoor MV vacuum circuit breaker 12KV HV VCB

used as 10kv /11KV /12KV substation outlet switches and  three-phase AC electric power system.

ZW32-40T outdoor medium voltage disconnector vacuum circuit breaker

the circuit breaker and the isolating switch can be combined to form a "combined circuit breaker"

36kV 40.5kV fixed type VCB vacuum circuit breakers VS1-40.5

Vacuum circuit breaker is the most commonly used type of high-voltage circuit breaker, mainly divided into two types: indoor type and outdoor type. We mainly focus on indoor 10-40KV vacuum circuit breakers.

35KV 40.5KV withdrawable type vacuum circuit breaker VCB VS1-40.5 1600A

VS1-40.5 VCB indoor high voltage vacuum circuit breaker is used in KYN61-40.5 switchgear. Mainly used in rated voltage 40.5kV, three-phase AC 50Hz power system

12KV 1600A Vacuum circuit breaker VD4 type VSG VS1-12 draw-out type

Rated current from 630A to 4000A and rated short circuit breaking current from 20kA to 50kA satisfies re quirements of various customers.

12345

The working principle of the vacuum circuit breaker is that once the circuit breaker contact is disconnected in a vacuum, the contact is ionized by the metal vapor in the contact and produces an arc. However, due to the rapid condensation of electrons, ions, and metal vapors generated in CB contact outside the arc, the arc is easily quenched, so dielectric strength can be quickly restored. The most important feature of a vacuum is that once an arc is created in a vacuum, it can be extinguished quickly due to the rapid increase in the dielectric strength of the vacuum.

Characteristics of vacuum circuit breaker

Compared with other types of circuit breakers, the insulation medium of vacuum circuit breakers has higher requirements on arc suppression performance. The pressure in the vacuum blocker is about 10-4 for the flood, which includes very few molecules in the blocker. This circuit breaker basically has the following two characteristics.

Compared with other insulating media used in circuit breakers, the circuit breaker is a superior insulating medium. It is superior to other media except for SF6 and air because these media are used at high pressure.

Application of vacuum circuit breaker

A vacuum circuit breaker is currently recognized as the most reliable medium voltage switching current interruption technology. It requires minimal maintenance compared to other circuit breaker technologies.

The technology is mainly suitable for medium voltage applications. For high-pressure vacuum technology has been developed, but it is not commercially feasible. The vacuum circuit breaker is suitable for both metal-clad switchgear and ceramic clad circuit breaker.

Supplier of vacuum circuit breaker

Zhejiang JGGY Electrical Co.,Ltd (jggyelectric.com), JGGY Electrical was established in 2007, specializing in the manufacture, sales and service of high-voltage electrical products. We mainly specializes for 6~42kV medium voltage electric (outdoor and indoor): load break switch, Disconnector, cutout fuse, Surge Arrester, vacuum circuit Breaker.  Over the years, JGGY have been successfully used in important fields such as electric power, communications, chemicals, mining, metallurgy, transportation, petroleum, and railways.