There are many electrical components in the high voltage switchgear, which can generally be divided into two categories: primary electrical components and secondary electrical components:

1, switch cabinet commonly used primary electrical components (main circuit equipment) mainly include current transformer, voltage transformer, ground switch, arrester (resistance and capacitance absorber), isolation switch, high voltage circuit breaker, high voltage contactor, high voltage fuse, transformer, high voltage live display, insulation (through the wall sleeve, contact box, insulator, insulation heat shrink sheath), high voltage reactor, load Switches, high-voltage single-phase shunt capacitors, etc.

2, the main secondary electrical components commonly used in the switch cabinet Secondary electrical components refer to the equipment for monitoring, control, measurement, adjustment and protection of primary equipment, mainly relays, watt-hour meters, ammeters, voltmeters, power meters, power factor meters, frequency meters, fuses, air switches, transfer switches, signal lights, resistors, buttons, microcomputer integrated protection devices.


TG3-24Q/175x255x218 bushing

It provides different specifications based on the size of electric current for the user’s choice

TG3-24Q/175x255x310 bushing

It provides different specifications based on the size of electric current for the user’s choice

TG3-35Q/260x260x395 bushing

It provides different specifications based on the size of electric current for the user’s choice

TG3-35Q/260x260x450 bushing

It provides different specifications based on the size of electric current for the user’s choice

202 double-pass casing

Epoxy resin cast insulators, sensor, connect with charged display device, used in switchgear application.

235 double-pass casing

Epoxy resin cast insulators, sensor, connect with charged display device, used in switchgear application.

Inflatable cabinet fuse

Epoxy resin cast insulators, sensor, connect with charged display device, used in switchgear application.

254 double-pass casing

Epoxy resin cast insulators, sensor, connect with charged display device, used in switchgear application.

260 double-pass casing (umbrella shape)

Epoxy resin cast insulators, sensor, connect with charged display device, used in switchgear application.

tee casing

Epoxy resin cast insulators, sensor, connect with charged display device, used in switchgear application.